   Transformer Turns Ratio Meters
  
  
    
      
        
          
            
              
                
                  
                    
                      |  |  |  |  |  
                      |  | 
                         Transformer Turns Ratio Tester |  |  |  
                      |  |  |  |  |  
                      | 
                        
                          
                            |  | Part Number(s) 9023-UC [ATRT-01 S3]
  View Full Specs |  
                            | 
                              The ATRT-01 S3 is Vanguard’s fourth generation, micro-processor based, single phase, automatic transformer turns-ratio tester. The ATRT-01 S3 uses the  measuring method to determine the transformer turns-ratio. The transformer turns-ratio is determined by precisely measuring the voltages across the unloaded transformer windings. The ATRT-01 S3’s measuring circuitry self adjusts before each measurement to ensure turns-ratio accuracy. Two selectable test voltages, 4Vac and 40Vac, offer flexibility in testing different types of transformers. | 
                              
                                Standalone or computer-controlledInexpensiveDisplays turns-ratio from 0.8-15,000Calculates turns-ratio percentage errorDisplays winding polarity and phase angleDisplays excitation current |  |  
                      |  |  
            
              
                
                  
                    
                      |  |  |  |  |  
                      |  | 
                         Transformer Turns Ratio Tester |  |  |  
                      |  |  |  |  |  
                      | 
                        
                          
                            |  | Part Number(s) 9036-UC [ATRT-01B S3]
  View Full Specs |  
                            | 
                              The ATRT-01B S3 is Vanguard’s fourth generation, micro-processor based, single phase, automatic transformer turns-ratio tester. The ATRT-01B S3 uses the  measuring method to determine the transformer turns-ratio. The transformer turns-ratio is determined by precisely measuring the voltages across the unloaded transformer windings. The ATRT-01B S3’s measuring circuitry self adjusts before each measurement to ensure turns-ratio accuracy. Two selectable test voltages, 4Vac and 40Vac, offer flexibility in testing different types of transformers. | 
                              
                                Standalone or computer-controlledInexpensiveDisplays turns-ratio from 0.8-15,000Calculates turns-ratio percentage errorDisplays winding polarity and phase angleDisplays excitation currentBattery or AC-Powered |  |  
                      |  |  
            
              
                
                  
                    
                      |  |  |  |  |  
                      |  | 
                         3-Phase Transformer Turns Ratio Tester |  |  |  
                      |  |  |  |  |  
                      | 
                        
                          
                            |  | Part Number(s) 9037-UC [110V ATRT-03]9038-UC [220V ATRT-03]
 
  View Full Specs |  
                            | 
                              The ATRT-03 is a three-phase, transformer turns-ratio tester. The Model ATRT-03 is lightweight, rugged, and portable, and is designed for transformer testing at utility power substations. The Model ATRT-03/03A determines the transformer turns ratio by accurately measuring the voltages across the unloaded transformer windings and then displaying the ratio of these voltages (ratios range from 0.8 to 15,000). The ATRT-03A calibrates each measurement to ensure the turns-ratio accuracy. | 
                              
                                Highest ratio: 0.8 - 15,000Built-in 4.5" thermal printerExcitation current measuringPhase angle measuringComputer interfaceName-plate turns ratio calculationComputed % error based on measured and calculated ratioAutomated phase switching |  |  
                      |  |  
            
              
                
                  
                    
                      |  |  |  |  |  
                      |  | 
                         3-Phase Transformer Turns Ratio Tester |  |  |  
                      |  |  |  |  |  
                      | 
                        
                          
                            |  | Part Number(s) 9003-UC [ATRT-03 S2]9003-PR [Printer Option]
 
  View Full Specs |  
                            | 
                              The Vanguard Instruments ATRT-03 S2 is the third generation, microprocessor-based, automatic, three phase, transformer turns-ratio tester. This light weight, rugged, portable unit is designed for transformer testing at utility power substations. | 
                              
                                Highest ratio: 0.8 - 15,000Capable of detecting 130 different 3-phase transformer types defined by 3 Test voltages available: 8Vac, 40Vac, 100VacPhase angle and excitation current measuringComputer Interface (RS-232C and USB Port)USB flash drive interfaceName-plate turns ratio calculationComputed % error based on measured and calculated ratioOptional 4.5" thermal printerPowered from a single phase 100-264 Vac 50/60 Hz |  |  
                      |  |  
            
              
                
                  
                    
                      |  |  |  |  |  
                      |  | 
                         3-Phase Transformer Turns Ratio Tester |  |  |  
                      |  |  |  |  |  
                      | 
                        
                          
                            |  | Part Number(s) 9042-UC [ATRT-03A S2]
  View Full Specs |  
                            | 
                              The Vanguard Instruments Company Model ATRT-03A Series 2 is Vanguard's third generation, microprocessor-based, automatic, three phase transformer turns-ratio tester. The ATRT-03A Series 2 determines the transformer turns ratio using the  measurement method. The ATRT-03A Series 2 generates and outputs an excitation voltage to the three transformer primary winding. The included secondary voltage is sensed and the transformer turns ratio is calculated. | 
                              
                                Capable of detecting 130 different 3-phase transformer types defined by  plus phase shifting transformersStore up to 128 transformer test-plans in Flash EEPROMStore up to 112 test records in Flash EEPROMBuilt-in USB Flash Drive InterfaceComputer Interface (RS-232C and USB Port)4.5 Inch thermal printerBuilt-in transformer load tap changerPowered from the built-in rechargeable lead acid batteries (3 hours) or a single phase 100-240 Vac 50/60 Hz. |  |  
                      |  |  
            
              
                
                  
                    
                      |  |  |  |  |  
                      |  | 
                         Capacitor Voltage Transformer Tester |  |  |  
                      |  |  |  |  |  
                      | 
                        
                          
                            |  | Part Number(s) 9025-UC [CVT-765]
  View Full Specs |  
                            | 
                              The Vanguard CVT-765 is a microprocessor-based, single phase, automatic, transformer turns-ratio tester. This portable test unit is specifically designed to measure the turns-ratios of Voltage Transformers (VT’s), Potential Transformers (PT’s), and Capacitor Voltage Transformers (CVT’s). | 
                              
                                Standalone or computer-controlledCan test CVT's rated up to 765 KVDisplays turns-ratios from 75-15,000Calculates turns-ratio percentage error when nameplate voltages are provided |  |  
                      |  |  
            
              
                
                  
                    
                      |  |  |  |  |  
                      |  | 
                         Automatic, 3-Phase Transformer Ratio Finder |  |  |  
                      |  |  |  |  |  
                      | 
                        
                          
                            |  | Part Number(s) 9105-UC [TRF-250]9105-PR [TRF-250 built-in thermal printer option]
 9105-SC [TRF-250 shipping case]
 
  View Full Specs |  
                            | 
                              The TRF-250 is Vanguard's fourth generation transformer turns ratio tester. This latest design provides a higher turns-ratio test voltage of 250Vac, provides a wireless Bluetooth PC interface, and features a 44-key "QWERTY"-style membrane keyboard. All these features greatly improve the accuracy of the turns ratio readings, ease of operation, and reliability. | 
                              
Ratio Range: 0.8 - 50,000 to 1Capable of detecting 130 different 3-phase transformer types defined by 4 test voltages: 4Vac, 40Vac, 100Vac, and 250VacPhase angle and excitation current measurementBluetooth and USB PC interfaces4.5-inch wide thermal printer (optional) |  |  
                      |  |  
            
              
                
                  
                    
                      |  |  |  |  |  
                      |  | 
                         True 3-Phase Transformer Turns Ratio Tester |  |  |  
                      |  |  |  |  |  
                      | 
                        
                          
                            |  | Part Number(s) 9008-UC [Tri-Phase]
  View Full Specs |  
                            | 
                              Vanguard’s new TRI-PHASE is a true 3-phase transformer turns ratio tester designed to conform to the  measurement method. The TRI-PHASE outputs a 3-phase excitation test voltage to the three transformer primary windings. The induced 3-phase secondary voltages are sensed and the transformer turns ratio is calculated. The TRI-PHASE is capable of measuring turns ratios from 0.8 to 15,000. The 3-phase excitation current, phase angle readings along with the turns ratios are displayed on the built-in LCD. | 
                              
                                Generates its own 3-phase transformer test voltage from single-phase AC or DC Power inputCapable of detecting 130 different 3-phase transformer types defined by  plus phase shifting transformers64 x 128 graphic LCD screenStore up to 128 transformer test-plans in Flash EEPROMStore up to 112 test records in Flash EEPROMBuilt-in USB Flash Drive InterfaceComputer Interface (RS-232C and USB Port)4.5 Inch thermal printerBuilt-in transformer load tap changerPowered from a single phase 100-264 Vac 50/60 Hz |  |  |