| TYPE | 10 – 600 Amp current source | 
            
              | PHYSICAL SPECIFICATIONS | 16.8”W x 12.6”H x 10.6” D (42.6 cm by 32.0 cm by 27 cm); Weight: 46lbs (21kg) | 
            
              | INPUT POWER | 100 – 120 Vac or 200 – 240 Vac (factory pre-set), 50/60 Hz | 
            
              | INTERNAL CURRENT METER | 100 mA – 1000 A; Accuracy: 1% of reading, ±20 mA | 
            
              | MEASURING METHOD | Isolated CT | 
            
              | EXTERNAL METER RANGE | 10 mA – 10 A; Accuracy: 1% of reading, ±2 mA | 
            
              | MEASURING METHOD | Isolated CT | 
            
              | TIMER READING RANGE | 1 ms – 2 hours; Accuracy: 0.1% of reading ±1ms | 
            
              | TIMER STOP INPUT | Voltage input (24 – 300 V, DC or peak AC), dry-contact input, or removal of primary current | 
            
              | COMPUTER INTERFACE | RS-232C port (19,200 baud) for factory calibration and diagnostics | 
            
              | SAFETY |  | 
            
              | ENVIRONMENT | Operating: -10C to 50 C (15F to +122 F); Storage: -30 C to 70 C (-22F to +158 F) | 
            
              | CABLES | 10-foot #1/0 AWG test leads, power cord, ground cable | 
            
              | OPTIONS | Transportation case | 
            
              | WARRANTY | One year on parts and labor | 
            
              | Specifications are valid at nominal voltage and ambient temperature of +25C (+77F). Last updated on February 13, 2009
 |