| DescriptionLIFASA automatic capacitor banks are used for centralized 
  compensation of power factor in low voltage installations.
 These equipments are supplied completely assembled and 
  ready for use: it is only necessary to connect it to the mains 
  with  cables  of  adequate  cross  section,  and  to  supply  the
 operation signal from a suitable current transformer.
  General   CharaCteristiCs  LIFASA automatic capacitor banks are composed of the following elements: High rupturing capacity (HRC) fuses connected to a busbar 
  system.
 Contactors specially adapted to the work with capacitors.
 Inrush current limiting inductances.
 Fast discharge resistors.
 Low losses power capacitors.
 Reactive power controllers.
 Terminals for neutral and ground conductors.
 Metal cabinet containing all the switchgear..
 Advantages
 Equipments wired and tested at works,  full  finished and 
  supplied with all control and safety devices.
 Easy transportation and installation due to their light weigh.
 Easy selection of the most appropriate cos φ to avoid penalty charges on tariffs.
 Long life and high reliability, thank to the use of self-healing and low losses capacitors.
 Wide range of power (from 5 to 1600 kvar, 440 V) with 
  standard equipments for immediate delivery.
 Option of including various accessories.
   Technical   characteristicsTensiones nominales/Rated voltages…………230 / 440 /690  V
 Frecuencia nominal/Rated frequency…………50 Hz - 60 Hz
 Potencia nominal/Rated power…………5 ... 1600 kvar
 Pérdidas dieléctricas/Dielectric losses…………< 0.2 W/kvar
 Pérdidas en los condensadores/Capacitors…………losses < 0.5 W/kvar
 Sobretensión máxima/Maximum overvoltage…………1.1 Un (8h/dia/day)
 Sobreintensidad máxima/Maximum overcurrent…………1.3 In
 Resistencia de descarga rápida/Fast discharge resistors…………En cada contactor/On each contactor
 Equipo de regulación/Regulation equipment…………Reguladores MCE ADV o PFCL Elite/MCE ADV or PFCL Elite controller
 Programas de trabajo/Working programs…………1:1:1:1 / 1:2:2:2 / 1:2:4:4 /1:2:4:8 / 1:1:2:2
 Tensión de maniobra/Control voltage…………230 V
 Conexión transformador de intensidad/External current transformer………… /5 (Opcional/Optional)
 Gama climática/Temperature range…………-23oC/+45 oC max. temp.
 Grado de protección/Degree of protection…………
 Instalación/Installation…………Interior/Indoor
 Normas/Standars…………, , ,
   Special   EquipmentOn request, automatic capacitor banks 
  can  be  produced  to  customers    special requirements. Among the different 
  possibilities are the following:
 Other voltages and frequencies.
 Capacitor  banks  with  different  degrees of protection.
 Capacitor  banks  for  outdoor  installation.
 Working program 1:2:4:4:, 1:2:4:8:,
  1:1:2:2:.
 Fixed step (for transformer compensation).
 Higher powers than the above stated.
 BATLV400    150-400 kvar 
AUTOMATIC CAPACITOR BANK c aracterísticas   técnicas /t eChniCal   CharaCteristiCsTensión nominal/Rated voltages....................440 V  50 Hz - 60 Hz
 Regulador/Controller ......................................MCE ADV
 Programa trabajo/Working program .............5 opciones/options
 Condensador/Capacitors ...............................Tipo/Type FML
 Protección/Protection steps ............................Fusibles/Fuses NH00
 Grado IP/Degree of protection ...................
 Color/Colour .....................................................Gris/Grey RAL 7035
 Instalación/Installation ....................................Interior/Indoor
 Montaje/Assembly ...........................................Sobre suelo/
 Floor mounting
 Dimensiones/Dimensions .................................650x460x1900mm
 a ccesorios /a CCessoriesInterruptor general de corte en carga ó automático /
 Main switch or Circuit breaker
 Protección diferencial / Leakage protection
 
  
  
  
  
  
  
  
  
    | Part    number | Qn (kvar) 440 V
 | Composition | Steps | Program | Qn (kvar) 400 V
 | (kg) Weight
 | () Price
 |  
    | BATLV4044150 | 150 | 2x25+2x50 | 6x25 | 1.1.2. | 124 | 195 | 4.701 |  
    | BATLV4044175 | 175 | 25+50+100 | 7x25 | 1.2.4. | 145 | 195 | 4.829 |  
    | BATLV4044187 | 187.5 | 12.5+25+50+100 | 15x12.5 | 1.2.4.8. | 155 | 200 | 4.956 |  
    | BATLV4044200 | 200 | 50+50+100 | 4x50 | 1.1.2. | 165 | 200 | 5.135 |  
    | BATLV4044225 | 225 | 25+50+50+100 | 11x25 | 1.2.2.4. | 182 | 205 | 5.56 |  
    | BATLV4044250 | 250 | 50+2x100 | 5x50 | 1.2.2. | 207 | 208 | 6.037 |  
    | BATLV4044275 | 275 | 25+50+2x100 | 11x25 | 1.2.4. | 227 | 210 | 6.539 |  
    | BATLV4044300 | 300 | 50+50+2x100 | 6x50 | 1.1.2. | 248 | 215 | 7.015 |  
    | BATLV4044350 | 350 | 50+3x100 | 7x50 | 1.2.2. | 289 | 220 | 7.492 |  
    | BATLV4044400 | 400 | 4x100 | 4x100 | 1.1.1. | 330 | 225 | 8.568 |  Other ratings, voltages and frequencies available on request.BATLV400 BATLV4044150	BATLV4044250
BATLV4044175	BATLV4044275
BATLV4044187	BATLV4044300
BATLV4044200	BATLV4044350
BATLV4044220	BATLV4044400
 |