| MASTER Control Var ADVANCED CONTROLLERDescription
 MASTER controller  has a built in power analyzer allowing the measurement of main electrical  parameters (voltage, current, harmonics, active and reactive power, apparent  power, etc.). The device gives a detailed information on both, voltage and current  harmonic components. MASTER controller  measures also ambient temperature and keeps a record of maximum and minimum  values of all measured parameters. All this information as  analyzer is possible  by using 1  or 3 current measurement transformer.
 Serial CommunicationsMASTER controllers  are equipped with RS-485 communication with MODBUS protocol. This allows the  integration of the PF regulator in a data network driven by a computer
 (PC). Enables data recording, remote control,  supervision and preventive maintenance of the PF correction equipment itself  and of the whole LV network.
 AUTO-ON-OFF  Function
 
 This function  allows to define the operating mode of each individual capacitor step:
 Automatic mode (Auto).
 Fixed mode (ON): Capacitor is always ON.
 Disconnected mode (OFF). Capacitor is  always OFF.
 
  
    | Part number
 | Model | Power (V) | Size (mm) | Steps | Price() |  
    | MASTER06 | MASTER Control Var 6 | 110…480 | 144x144 | 6 | 325 |  
    | MASTER12 | MASTER Control Var 12 | 110…480 | 144x144 | 12 | 400 |  
    | MASTER14 | MASTER Control Var 14 | 110…480 | 144x144 | 14 | 425 |  Plug and Play A series of  parameters must be configured when a power factor regulator is installed, to  make sure that it operates correctly. Some of these parameters might be hard to  know, such as, for example, the voltage phases or the voltage corresponding to  the current measured, as well as the current transformer ratio. MASTER has been  designed with a smart automatic process that detects the necessary parameters, such  as:
 C/K: calculates the ratio of the current  transformer and the power of the smallest step.
 Phase: Identifies the voltage sequence  and correspondence with current. In other words, it identifies the UL1, UL2, UL3,  when the current measured is IL1, IL2, I
 L3 and whether it  is connected in the opposite way or not.
 Number of stages installed and Program: The  system connects all stages in a sequence, finds out how many stages are  installed and then calculates the program,
 i.e., the power  ratio of the capacitors.
 Built-in leakage control
 MASTER have a  built-in circuit to measure the earth leakage current through a WGC  transformer. The regulator is able to measure the individual leakage of each  capacitor. This allows to disable a damaged capacitor if an excess of leakage  current is detected without interrupting the supply service.
 Safety and maintenance
 MASTER performs a capacitor test every  time that a capacitor step is switched ON. The real power and the leakage current  of each step can be displayed.
 Up to 14 different alarm conditions can be  programmed.
 Internal counter register which counts the  number of operations of each individual capacitor step
 Digital inputs
 Digital outputs
 Fan relay with internal sensor for forced ventilation
 Set up of 4 different cos φ for compensation in  different time periods
 Suitable for medium voltage automatic capacitor banks
 Note: Version for  static switches with thyristors (on request)
 Technical   Characteristics 
  
  
  
    | Power    supply | 110 ... 480V ac    ±10 %; 50 / 60 Hz ±10 % |  
    | Voltage    measurement | Up to 525 V a.c. PP/    300 V a.c. PN |  
    | Power supply    cables | Section 1,5 mm2 , gl 0.5 to 2 A protection fuse |  
    | Current    measurement circuit | 1    or 3 current transformer (CT), .../5 A or .../1 A, Min. cable section. 2.5 mm2
 |  
    | Leakage    current measurement circuit | Nominal    current of transformer secondary: Isec = 2 mA AC. Current transformer type WGC
 |  
    | Current    measurement margin | Current    I: 0.05 ... 5 A AC (maximum overload    +20%) Leakage current I: 0.01 ... 1 A AC(maximum overload +20%)
 |  
    | Measurement    accuracy | Voltage    and current: 1 %; cos φ : 2 % ±    1 digit |  
    | Temperature    measurement | External    temperature approximation. Range: 0 ... 80oC. Accuracy: ± 3 oC |  
    | Consumption | 8.2    VA (empty); 9.3 VA (6 relays); 11 VA (12 relays) |  
    | Output | Relays.    Contacts for Umax. 250 Vac., 4 A AC., AC1. |  
    | Cabling and    output relay protection | Cable    section 1.5 mm2, protection with circuit breaker (C curve) of 6 A or gl 6 A fuse
 |  
    | Alarm relay | Switched    relay for use exclusively for the alarms |  
    | Standards | /-6-3
 |  
    | Safety/Insulation | Category    III, Class II , according to |  
    | Protection    degree | (equipment mounted, cabinet front panel) IP30 (equipment not mounted) according to
 |  
    | Admissible    environmental conditions | Temperature:    -20 ... +60oC; Relative humidity: max.    95% (without condensation). Max. altitude: 2000 m |  
    | Control    system | FCP    (a program that minimises the number of operations) |  
    | Communications | Interface:    RS485. Protocol: MODBUS. Speed: 9600, 19200, 38400 |  Reactive Power ControllersDescription
 Reactive power  controllers MCE ADV, PFCL and MASTER are designed to measure the reactive power  of an installation and to give the necessary instructions for connecting and  disconnecting capacitors in order to maintain the desired cos φ .
 All the  controllers are commanded by a microprocessor that ensures an uniform ageing of  contactors and capacitors by using a circular connection sequence that takes  into account the time that each capacitor has been switched on.
 Power factor value  to be reached can be adjusted in a continuous way, between 0.85 inductive and  0.95 capacitive.
 Standard working programs  for controllers are 1:1:1:1,
 1:2:2:2, 1:2:4:4,  1:2:4:8 and 1:1:2:2.
 Advantages
 Uniform ageing of the capacitors and  contactors
 High speed operation with less number of  switchings
 True rms measuring circuit, insensitive to  harmonics
 Automatic disconnection of all the  capacitors in the case of
 a failure in the electrical network
 Detection and automatic indication of  current transformer
 wrongly connected
 Digital cos φ display
 Adjustable operation delay
 Power factor alarm relay (PFCL/MASTER)
 Harmonic distortion alarm relay  (PFCL/MASTER)
 Some others advanced features, depending  on the model.
 Range
 MCE ADV, of  6 or 12 steps, for standard automatic  bank.
 PFCL,  available with 6 and 12 relays, size 144x144mm with special alarms and  communication.
 MASTER,  available with 6, 12 and 14 relays, size 144x144mm with special alarms and communication.
 |    | 
 |