| DescriptionLIFASA automatic capacitor banks are used for centralized 
  compensation of power factor in low voltage installations.
 These equipments are supplied completely assembled and 
  ready for use: it is only necessary to connect it to the mains 
  with  cables  of  adequate  cross  section,  and  to  supply  the
 operation signal from a suitable current transformer.
  General   CharaCteristiCs  LIFASA automatic capacitor banks are composed of the following elements: High rupturing capacity (HRC) fuses connected to a busbar 
  system.
 Contactors specially adapted to the work with capacitors.
 Inrush current limiting inductances.
 Fast discharge resistors.
 Low losses power capacitors.
 Reactive power controllers.
 Terminals for neutral and ground conductors.
 Metal cabinet containing all the switchgear..
 Advantages
 Equipments wired and tested at works,  full  finished and 
  supplied with all control and safety devices.
 Easy transportation and installation due to their light weigh.
 Easy selection of the most appropriate cos φ to avoid penalty charges on tariffs.
 Long life and high reliability, thank to the use of self-healing and low losses capacitors.
 Wide range of power (from 5 to 1600 kvar, 440 V) with 
  standard equipments for immediate delivery.
 Option of including various accessories.
   Technical   characteristicsTensiones nominales/Rated voltages…………230 / 440 /690  V
 Frecuencia nominal/Rated frequency…………50 Hz - 60 Hz
 Potencia nominal/Rated power…………5 ... 1600 kvar
 Pérdidas dieléctricas/Dielectric losses…………< 0.2 W/kvar
 Pérdidas en los condensadores/Capacitors…………losses < 0.5 W/kvar
 Sobretensión máxima/Maximum overvoltage…………1.1 Un (8h/dia/day)
 Sobreintensidad máxima/Maximum overcurrent…………1.3 In
 Resistencia de descarga rápida/Fast discharge resistors…………En cada contactor/On each contactor
 Equipo de regulación/Regulation equipment…………Reguladores MCE ADV o PFCL Elite/MCE ADV or PFCL Elite controller
 Programas de trabajo/Working programs…………1:1:1:1 / 1:2:2:2 / 1:2:4:4 /1:2:4:8 / 1:1:2:2
 Tensión de maniobra/Control voltage…………230 V
 Conexión transformador de intensidad/External current transformer………… /5 (Opcional/Optional)
 Gama climática/Temperature range…………-23oC/+45 oC max. temp.
 Grado de protección/Degree of protection…………
 Instalación/Installation…………Interior/Indoor
 Normas/Standars…………, , ,
   Special   EquipmentBATLV180On request, automatic capacitor banks 
  can  be  produced  to  customers    special requirements. Among the different 
  possibilities are the following:
 Other voltages and frequencies.
 Capacitor  banks  with  different  degrees of protection.
 Capacitor  banks  for  outdoor  installation.
 Working program 1:2:4:4:, 1:2:4:8:,
  1:1:2:2:.
 Fixed step (for transformer compensation).
 Higher powers than the above stated.
 BATLV1844090	BATLV1844120
BATLV1844095	BATLV1844125
BATLV1844100	BATLV1844135
BATLV1844105	BATLV1844137
BATLV1844110	BATLV1844142
BATLV1844112	BATLV1844150
BATLV1844119	BATLV1844165
BATLV1844180
 |