| TYPE | Portable circuit-breaker analyzer | 
            
              | PHYSICAL SPECIFICATIONS | 16”W X 11”H x 14”D (40.6 cm x 29.9 cm x 35.6 cm); Weight: less than 25 lbs (11.3 kg) | 
            
              | INPUT POWER | 100 – 120 Vac or 200 – 240 Vac (selectable), 50/60Hz | 
            
              | DRY-CONTACT INPUTS | 3, 6 or 12 dry-input channels (depending on model). Each channel detects main and insertion-resistor contacts | 
            
              | TIMING WINDOWS | 1-second, 10-seconds, or 20-seconds | 
            
              | TIMING RESOLUTIONS | ±50 micro-seconds @ 1-second duration, ±500 micro-seconds @ 10-second duration, ±1.0 milli-seconds @ 20-second duration | 
            
              | TIMING ACCURACY | 0.05% of reading ±0.05 ms @ 1-second duration | 
            
              | DRY-CONTACT CHANNEL PROTECTION | All contact inputs are grounded until test; input channels are protected against static discharge | 
            
              | DRY CONTACT DETECTION RANGE | Closed: less than 20 ohms; Open: greater than 5,000 ohms | 
            
              | RESISTOR DETECTION RANGE | 50 – 5,000 ohms | 
            
              | TRIGGER INPUT VOLTAGE | Open/Close: 30 – 300V, DC or peak AC | 
            
              | VOLTAGE SENSING INPUT RANGE | V1: analog input; 0 – 255V DC or peak AC; Sensitivity ±1V V2: voltage presence/absence detector input; 30 – 300V DC or peak AC
 | 
            
              | BREAKER OPERATIONS | Initiate Open, Close, Open– Close, Close – Open, Open – Close – Open | 
            
              | BREAKER INITIATE CAPACITY | 30A, 250Vac/dc max | 
            
              | INITIATE CURRENT READING RANGE | One, non-contact, Hall-effect sensor, 0 – 20 amp range, dc to 5Khz | 
            
              | DIGITAL TRAVEL TRANSDUCER INPUTS | 3 digital travel transducer channels; Linear range, 0.0 – 60.0 in (±0.01 in); Rotary range: 0 – 360 degrees (±0.36 degrees) | 
            
              | OPTIONAL RESISTOR TYPE TRANSDUCER INPUT | 200 Ohms – 10K Ohms | 
            
              | CONTACT TRAVEL POINT DIFFERENCE | Measures “slow-close” contact-point distances; results can be printed | 
            
              | DISPLAY | Back-lit LCD Screen (20 characters by 4 lines); viewable in bright sunlight and low-light levels | 
            
              | PRINTER | Built-in 4.5-inch wide thermal printer can print both graphic contact travel waveforms and tabulated test results | 
            
              | INTERNAL TEST RECORD STORAGE | Stores up to 150 test records and 99 test plans | 
            
              | COMPUTER INTERFACES | One RS-232C port, One USB port | 
            
              | PC SOFTWARE | Windows XP/Vista-based Breaker-Analysis software is included with purchase price | 
            
              | SAFETY |  | 
            
              | ENVIRONMENT | Operating: -10°C to 50°C (+15°F to +122°F); Storage: -30°C to70°C (-22°F to +158°F) | 
            
              | OPTIONS | Transportation case (available for the CT-7000 S2 and the travel transducers) | 
            
              | WARRANTY | One year on parts and labor | 
            
              | Specifications are valid at nominal voltage and ambient temperature of +25C (+77F). Last updated on February 5, 2009
 |