| PFCL ELITE ADVANCED CONTROLLERDescription
 PFCL Elite  controller has a built in power analyzer allowing the measurement of main electrical  parameters (voltage, current, harmonics, active and reactive power, apparent  power, etc.). The device gives a detailed information on both, voltage and  current harmonic components. PFCL Elite controller measures also ambient  temperature and keeps a record of maximum and minimum values of all measured  parameters.
 - Serial  Communications- AUTO-ON-OFF  Function
 - Plug and Play
 - Built-in leakage  control
 - Safety and  maintenance
  PFCL Elite performs a capacitor test every  time that a capacitor step is switched ON. The real power and the leakage  current of each step can be displayed.Up to 14 different alarm conditions can be  programmed.
 Internal counter register which counts the  number of operations of each individual capacitor step
 ALSO AVAILABLE FAST VERSION FOR STATIC CONTACTORS WITH  THYRISTORS
 
  
    | Part number
 | Model | Power (V) | Size (mm) | Steps | Price() |  
    | PFCL06230 | PFCL Elite 6 | 230 | 144x144 | 6 | 300 |  
    | PFCL06400 | PFCL Elite 6 | 400 | 144x144 | 6 | 275 |  
    | PFCL12230 | PFCL Elite 12 | 230 | 144x144 | 12 | 350 |  
    | PFCL12400 | PFCL Elite 12 | 400 | 144x144 | 12 | 325 |  
    | PFCL06110 | PFCL Elite 6 | 110 | 144x144 | 6 | 300 |  Reactive power controllers PFCL Elite|    | 
 PFCL06230 PFCL Elite 6
PFCL06400 PFCL Elite 6
PFCL12230 PFCL Elite 12
PFCL12400 PFCL Elite 12
PFCL06110 PFCL Elite 6
 Reactive Power ControllersDescription
 Reactive power  controllers MCE ADV, PFCL and MASTER are designed to measure the reactive power  of an installation and to give the necessary instructions for connecting and  disconnecting capacitors in order to maintain the desired cos φ .
 All the  controllers are commanded by a microprocessor that ensures an uniform ageing of  contactors and capacitors by using a circular connection sequence that takes  into account the time that each capacitor has been switched on.
 Power factor value  to be reached can be adjusted in a continuous way, between 0.85 inductive and  0.95 capacitive.
 Standard working programs  for controllers are 1:1:1:1,
 1:2:2:2, 1:2:4:4,  1:2:4:8 and 1:1:2:2.
 Advantages
 Uniform ageing of the capacitors and  contactors
 High speed operation with less number of  switchings
 True rms measuring circuit, insensitive to  harmonics
 Automatic disconnection of all the  capacitors in the case of
 a failure in the electrical network
 Detection and automatic indication of  current transformer
 wrongly connected
 Digital cos φ display
 Adjustable operation delay
 Power factor alarm relay (PFCL/MASTER)
 Harmonic distortion alarm relay  (PFCL/MASTER)
 Some others advanced features, depending  on the model.
 Range
 MCE ADV, of  6 or 12 steps, for standard automatic  bank.
 PFCL,  available with 6 and 12 relays, size 144x144mm with special alarms and  communication.
 MASTER,  available with 6, 12 and 14 relays, size 144x144mm with special alarms and communication.
 |    | 
 |