                                                  | PD-20   High Voltage Testers H.V.  Probe
 Input Impedance : 500M Ohm
 |  
                                                  |  |  | 
                                                
                                                
                                                  | FEATURES |  
                                                  |  |  
                                                  |  PD-20 and PD-28 have the same shape and color but different specifications. |  
                                                  |  Meet |  
                                                  |  PD-20 is a high voltage probe that is used with DMM |  | 
                                          
                                            | 
                                                
                                                
                                                  |  PD-20 and PD-28 are high voltage probes. They measure both AC and DC voltages with your multimeter. They consist of 2 kinds of contact tips, a test clip for the ground, a set of test leads for multimeter and a high qualify enclosure. The enclosure has very good insulation properties. |  
                                                  |  They are lightweight and ruged. Two kinds of contact tips are avaialble. One is a round needle tip for normal use. Another is a special flat spring type for CRT anode. |  
                                                  |  Before taking any measurements, first connect the alligator clip of this probe to earth ground and amke sure connection is proper. |  | 
                                          
                                            | 
                                                
                                                
                                                  | SPECIFICATIONS |  
                                                  |  |  
                                                  | Input Impedance | 500M Ohm. |  
                                                  | Attenuation Ratio | 1000 : 1 |  
                                                  | Accuracy | DCV (0 ~ 20kV) +/- 1%, DCV (20kV ~ 30kV) +/- 2%, ACV (0 ~ 20 kV) typically +/- 5% at 60Hz |  
                                                  | Max. Working Voltage | 30kV DC or 20kV AC |  
                                                  | Operating Temperature | 0 degree C ~ 50 degree C |  
                                                  | Storage Temperature | -10 degree C ~ 60 degree C |  
                                                  | Cable Length | 1m |  
                                                  | Weight | Approx. 260g |  |