                                                  | 4112 EL   ELCB Testers Up To 500mA
 |  
                                                  |  |  | 
                                                
                                                
                                                  | FEATURES |  
                                                  |  |  
                                                  |  2 Lines x 16 Characters L.C.D. |  
                                                  |  Very low consumption. |  
                                                  |  Microprocessor controlled. |  
                                                  |  Menu Driven. |  
                                                  |  Accurate digital readout of disconnection time. |  
                                                  |  Automatic data hold function. |  
                                                  |  Zero crossing circuitry permit testing at 0 degree or 180 degree. |  
                                                  |  Disconnection phase polarity shown on L.C.D. display. |  
                                                  |  Auto-off and Off override. |  
                                                  |  Polarity trip indicator (positive or negative phase). |  
                                                  |  Wiring polarity indicator. |  
                                                  |  Measure voltage between line and earth before testing. |  
                                                  |  CAT III 300V. |  
                                                  |  Indicates frequency of voltage L-E. |  |  
                                            |  |  
                                            | 
                                                
                                                
                                                  | SPECIFICATIONS |  
                                                  |  |  
                                                  | Current Settings | 3mA, 5mA, 7mA, 10mA, 15mA, 20mA, 30mA, 35mA, 50mA, 100mA, 125mA, 150mA, 175mA, 250mA, 300mA, 375mA, 500mA |  
                                                  | Current Selection | Rotary switch selector |  
                                                  | Phase Start Selection 0 degree and 180 degree | Referenced to Earth Yes |  
                                                  | Over-temperature Protection | Yes |  
                                                  | Wiring Correctness Indication | Yes |  
                                                  | Trip Indicator | Yes |  
                                                  | Phase Polarity Trip Indicator | Yes |  
                                                  | Operating Voltage (L-E) | Referenced to Earth 240Vac - 50Hz or 60Hz Voltage Model (Vac) |  
                                                  | Timer Resolution | 1mS (max time = 19.99s) |  
                                                  | Timer Accuracy | 1mS +/- 1mS |  
                                                  | Current Accuracy | +/- 5% +/-1mA |  
                                                  | Operating Temperature | -5 degree C to 45 degree C |  
                                                  | Storage Temperature | -10 degree C to 85 degrcc C |  
                                                  | Power Source | 1.5V (AA) x 8 batteries, Bat OK Led = Vbat > 7.5V |  
                                                  | Dimensions | 250(L) x 190(W) x 110(D) mm |  
                                                  | Weight | Approx. 1500g (battery included) |  
                                                  | Accessories | Test leads, shoulder belt, Instruction manual, batteries |  |  
  
    | 特 點 |  
    | ● 微處理器系統(tǒng)控制設(shè)計。● 操作電壓110-450V(L-E)。
 ● 檢查核對斷路器跳脫時間和跳脫電流。
 ● 可選擇相位(0度和180度)。● 自動換檔。
 ● 自動關(guān)機。
 ● 過熱保護。
 ● 可供重工業(yè)設(shè)備量測。
 ●   保險絲保護設(shè)計。
 ● 符合EN 61010-1 CAT Ⅲ 300V
 EN 61326-1
 |  
    |  |  
    | 規(guī) 格 (23°C±5°C   <80%R.H.) |  
    |  |  |