| SPECIFICATIONS | 
                                                
                                                  |  | 
                                                
                                                
                                                
                                                  | Measuring Ranges | Earth Resistance : 0-20 Ohm/0-200 Ohm/0-2000 Ohm | 
                                                
                                                
                                                
                                                  |  | Earth Voltage : 0-200V AC (40-500Hz) | 
                                                
                                                
                                                
                                                  | Accuracy | Earth Resistance : +/- (2%rdg+2dgt) | 
                                                
                                                
                                                
                                                  |  | Earth Voltage : +/- (1%rdg+2dgt) | 
                                                
                                                
                                                
                                                  | Earth Resistance Resolution | 0-20 Ohm (0.01 Ohm) | 
                                                
                                                
                                                
                                                  |  | 0-200 Ohm (0.1 Ohm) | 
                                                
                                                
                                                
                                                  |  | 0-2000 Ohm (1 Ohm) | 
                                                
                                                
                                                
                                                  | Measuring System | Earth Resistance by constant current inverter 820 Hz approx. 2mA | 
                                                
                                                
                                                
                                                  | Low Battery Indication | symbol appears on the diaplay | 
                                                
                                                
                                                
                                                  | Data Hold Indication | symbol appears on the display | 
                                                
                                                
                                                
                                                  | Over Range Indication | "1" (MSD) | 
                                                
                                                
                                                
                                                  | Open Circuit Indication | LED will be unlit | 
                                                
                                                
                                                
                                                  | Display LCD | LCD 3-1/2 digit (2000 counts) | 
                                                
                                                
                                                
                                                  | Power Source | 1.5V (R6P)  x 8 Type AA | 
                                                
                                                
                                                
                                                  | Dimensions | 170(L) x 165(W) x 92(D) mm | 
                                                
                                                
                                                
                                                  | Weight | Approx. 1050g (battery included) | 
                                                
                                                
                                                
                                                  | Accessories | Test leads (AL-36 : red-15m, yellow-10m, green-5m) | 
                                                
                                                
                                                
                                                  |  | Auxiliary earth spikes | 
                                                
                                                
                                                
                                                  |  | Simplified measurement probe, shoulder belt | 
                                                
                                                
                                                
                                                  |  | Instruction manual, batteries |